BIDP guide on building fire safety |
|
|
Statistics on building fires in Botswana |
From data on web site of Statistics Botswana, 2019
|
|
Information & communication technology |
Access room: provides an escape route for an Inner room
Disability and handicap
'Disability” and 'handicap' are not synonymous. A disabled person is not automatically a handicapped person, whether or not there is a handicap depends on the nature of the individual's impairment/s and the circumstance in which they are placed.
Disabled people means people who have:
an impairment which limits their ability to walk or which requires them to use a wheelchair or other device/s for enabling mobility or
impaired hearing or sight
Inner room: where the only escape is via another Access room
Building purpose groups (bw 1981) |
|||
| A Multistorey buildings | B Single storey buildings | ||
|---|---|---|---|
| I | Private residential (houses including flats and maisonettes- (a) up to three stories (b) more than three stories) | Private residential | |
| II | Institutional | Institutional | |
| III | Other residential | Other residential | |
| IV | Office | Office | |
| V | Factory | Factory | |
| VI | Shop | Shop | |
| VII | Assembly | Assembly | |
| VIII | Storage and General | Storage and General | |
|
|
|
(K) Fire, Explosion |
|
(K1) Fire types, sources |
|
(K2) Fire protection |
|
1 Retardant treatment |
|
2 Spread prevention including fire stopping |
|
| Section 8: Compartmentation | |
| Maximum compartment size | |
|---|---|
| I | Residential dwellings |
| Single storey | No requirement |
| Multi-storey | ![]() |
| II | Institutional |
| Single storey | ![]() |
| Multi-storey | ![]() |
| III | Other residential |
| Single storey | ![]() |
| Multi-storey | ![]() |
| IV | Office |
| Single storey | No requirement |
| Multi-storey | ![]() |
| V | Shop |
| Single storey | No requirement |
| Multi-storey | ![]() |
| VI | Factory |
| Single storey | No requirement |
| Multi-storey | ![]() |
| VII | Assembly |
| Single storey | No requirement |
| Multi-storey | ![]() |
| VIII | Storage and general |
| Single storey | No requirement |
| Multi-storey | ![]() |
| Section 9: Concealed spaces (cavities) |
| Section 10: Protection of openings and fire-stopping |
| Section 12: Construction of external walls |
| Section 13: Space separation |
3 Control including fire fighting, venting |
| Section 15: Fire mains |
| Section 16: Vehicle access |
| Section 17: Venting of heat and smoke from basements |
| Section 18: Access to building for firefighting personnel |
Fire engine access |
| 1-Buildings without wet or dry risers |
|
|
|
|
|
|
|
|
|
| 2-Any building with dry riser |
|
| 2-Any building with wet riser |
|
| Flats and maisonettes over two storeys |
| 1-Blocks with dry risers |
|
| 2-Blocks with wet risers |
|
| 3-Blocks without wet or dry risers |
|
2.4 Means of escape |
| Section 2.4.1: Dwelling houses |
|---|
Habitable rooms, used for dwelling purposes, should open directly onto a hall or stairway
|
| Section 2.4.2: Flats and maisonettes |
| Section 2.4.3: Horizontal escape for buildings other than dwellings |
| Section 2.4.4: Vertical escape for buildings other than dwellings |
| Section 2.4.5: General provisions for buildings other than dwelling houses |
| Section 2.4.11: Car parks and shopping complexes |
(K3) Fire resistance (structures) |
Structural precautions |
| Section 7: Loadbearing elements of structure |
| Structural element fire resistance | |
|---|---|
| I | Residential dwellings |
| Single storey | ![]() |
| Multi-storey | ![]() |
(K4) Reaction to fire (materials) |
| Section 6: Wall and ceiling linings |
| Section 14: Roof coverings |
1 Combustibility including combustible, non-combustible (incombustible) |
2 Calorific value (thermal value) |
3 Fire load, heat release rate |
4 Ignitability including ignition temperature (fire point), flash point |
5 Flammability (inflammability), flame spread |
(K5) Combustion products |
Smoke, fumes, soot |
(K6) Explosions |
Arresting, venting: explosive limits (gases and vapours) |
(K7) Fire and explosion damage, salvage |
(K8) Other factors relating to fire, explosion |
David Young 2020
Abang Onius Thibelang 2020
Leruo Lantern 2020
|
code |
title |
author |
published |
publisher |
|---|---|---|---|---|
|
dffs |
Designing for Fire Safety |
E Gordon Butcher and Alan C Parnell |
1983 |
John Wiley and Sons Ltd, |
|
sanbr |
Code of practice for the application of the National Building Regulations |
Council of the SA Bureau of Standards |
First revision |
SABS |
|
dfd |
Designing for the disabled |
Selwin Goldsmith |
Third revision 1976 reprinted 1992 |
RIBA Publications |
|
bbr |
Botswana Building Control |
RB government |
1962, 1977, 1981 |
RB government, Gaborone |
|
utbr |
Understanding the Building Regulations |
Simon Polley |
First edition 1995, reprinted 1996, 1997 |
E & FN Spon, London |